This is electrical automatic incinerator. 50 per day Capacity machine. 7 Pads per cycle.
| Type | Wall Mountable |
| Purpose | Burn used Sanitary Napkins to sterile ash and stop automatically |
| Color | Black, Blue, Green |
| Operation Mode | Electronically operated, fully Automatic |
| Loading Type | Front loading |
| Stand provided | No |
| Number of chambers | 2 |
| Trap Door available | Yes |
| All MS parts Powder coated | Yes |
| Spare parts should be available for Minimum 5 years from date of supply | Yes |
| All electrical parts are ISI Marked | Yes |
| Thickness of thermal Insulation material (mm) | 25 millimeter |
| Thickness of MS/SS sheet of housing cabinet (external) (mm) | 1.2 millimeter |
| Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) | 3 millimeter |
| Machine Width(mm) | 200-300 |
| Machine Depth (mm) | 201-300 |
| Machine Hight(mm) | 501-700 |
| Machine Weight(kg) | 5-15 |
| Door width(mm) | 101-150 |
| Door height(mm) | 101-150 |
| Thickness of door including insulation (mm) | 20 millimeter |
| Internal/burning chamber shape | Rectangular cubical |
| Flexible emission Outlet pipe dia (mm) | 25 millimeter |
| Detachable ash tray length (mm) | 100-150 |
| Detachable ash tray width (mm) | 100-150 |
| Detachable ash tray height (mm) | 5-15 |
| Stand Height (mm) | 0 millimeter |
| Stand Width (mm) | NA for wall mountable |
| Stand Depth (mm) | NA for wall mountable |
| Material of Housing cabinet (External) | Mild Steel(CRCA) sheet |
| Material of Burning chamber (Internal) | Mild Steel(CRCA) sheet |
| Finish of MS parts of cabinet | Epoxy anti rust proof painting |
| Material of Thermal Insulation | High Density Ceramic Fiber sheet |
| Thermal insulation of burning chamber housed in outer chamber | Yes |
| Burning Chamber tray provided | Yes |
| Emission Outlet pipe location | Top of machine |
| Means of connecting the unit outlet with flue gas emission pipe | Clamped |
| Type of door lock provided | Magnetic lock, Latch |
| Temperature indicator provided | Yes |
| Timer provided | Yes |
| Auto cut-off temperature display | Yes |
| Digital display to see actual and set temperature | Yes |
| Minimum Burning temperature (degree C) | 800 | Burning Capacity per day (Number of Napkins) | Approx 50 |
| Burning Capacity at a time (Number of Napkins) | 1-15 |
| Residue Ash per Napkin (gms) | 1 gram |
| Burning time of full capacity Napkins/pads (minutes) (Max) | 10 minute |
| Skin temperature of the unit under operation (deg C) | 16-20 |
| Installation, training, demonstration and plumbing included | Yes |
| Automatic digital controller for time | Yes |
| Automatic digital controller for temperature | Yes |
| Equipment ON/OFF indicator provided | Yes |
| Power supply | 230v +/-10%, 50Hz, Single phase, AC supp |
| Electrical Power Consumption(Watt) | 1000 |
| Minimum length of power chord to be supplied along with machine (mtr) | 1.5 |
| Type of Heater | Ceramic heater containing coil |
| Power saver (auto power cut-off) | Yes |
| Safety MCB provided (16A to 30A) | Yes |
| Protection against electric shock when checked as per IS:302-1/2008 | Yes |
| Minimum Insulation Resistance (IR) at 500 VDC (Mega Ohm) | 2 |
| Maximum Electrical Insulation and Leakage current as per IS:302-1/2008, (mA) | 0.21 |
| Maximum Earthing continuity test when tested as per IS:302-1/2008 (Ohm) | 0.1 |
| HV test at 1000 V rms for 1 Sec when tested as per IS:302-1/2008 | No breakdown shall occur during the test |
| Type of SCU (Smoke Control Unit) | -- |
| Material of housing of Smoke Control Unit (SCU) | -- |
| Finish of MS parts of SCU cabinet | -- |
| Overall height of SCU (mm) | -- |
| Overall width of SCU (mm) | -- |
| Overall depth of SCU (mm) | -- |
| Number of chambers for filteration of smoke emission | -- |
| Both carbon Control and Foul odour Control Chambers for filteration of smoke emission | -- |
| Type of filters in Carbon control chamber | -- |
| Number of filters in Odour control chamber | -- |
| Type of filters in Odour control chamber | -- |
| Blower type | -- |
| Blower RPM | -- |
| Power supply of SCU | -- |
| Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) | -- |
| Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user | -- |
| Conformity to CPCB, Min of Environment & Forests standard, Solid Waste Management Rules (SWM), 2016 | Yes |
| Particulates (Half hourly average) (mg/Nm3) (Max) | 50 |
| HCl (Half hourly average) (mg/Nm3) (Max) | 50 |
| SO2 (Half hourly average) (mg/Nm3) (max) | 200 |
| CO (Half hourly average) (mg/Nm3) (Max) | 100 |
| CO (Daily average) (mg/Nm3) (Max) | 50 |
| Total Organic Carbon (Half hourly average) (mg/Nm3) (Max) | 20 |
| HF (Half hourly average) (mg/Nm3) (Max) | 4 |
| "Nox (NO and NO2 expressed as NO2) (Half hourly average) (mg/Nm3) (Max)" | 400 |
| Total dioxins and furans ( 6 to 8 hours sampling basis, Please refer guidelines for 17 concerned congeners for toxic equivalence values to arrive at total toxic equivalence) (ng TEQ/Nm3) (Max) | 0.1 |
| Cd + Th + their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) | 0.05 |
| Hg and its compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) | 0.05 |
| Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V+their compounds (Sampling time anywhere between 30 minutes and 8 hours) (mg/Nm3) (Max) | 0.5 |
| Loss on ignition (max) (% dry weight of the material) | 5 |
| Type of Packing | Carton Box |
| Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1 |